🔬Big Data Meets Cortisol: Redefining Reference Ranges for Cushing Syndrome Diagnosis
May 19, 2025
A groundbreaking 2025 study from the European Journal of Endocrinology is reshaping how we interpret 24-hour urine-free cortisol (UFC) in suspected Cushing syndrome (CS). With over 4,800 patient samples analyzed using liquid chromatography–mass spectrometry (LC-MS/MS), researchers led by Dr. Gregory Kline leveraged big data to define a validated, population-relevant UFC reference range.
This massive effort required not only powerful analytics—but also ultra-precise measurement tools. Enter: Mass Spect Gold Human Urine (MSG5000) from Golden West Diagnostics. Used to spike cortisol standards into verified blank urine, MSG5000 played a pivotal role in establishing a clean, interference-free calibration curve for the mass spectrometry assay.
🧪 Study Design
The team conducted both a retrospective (4,830 samples) and prospective (120 patients) analysis within Alberta's public health system. All subjects had potential signs of CS, but only non-CS patients were used to define the reference range.
- Reference intervals derived using the refineR algorithm
- Comparison between retrospective and prospective cohorts
- Sex-specific upper reference limits established
📊 Key Findings
Sex Matters in Cortisol Excretion
Upper limits for daily UFC excretion were 238 nmol/day (86.3 μg/day) for men and 147 nmol/day (53.3 μg/day) for women—highlighting the need for sex-specific interpretation.
Skewed Distributions Demand Caution
The UFC data was highly skewed, underscoring the importance of contextual interpretation and ruling out pseudo-Cushing’s with secondary confirmation.
Volume Correction Normalizes Sex Differences
When adjusted for urine volume, male and female distributions converged (~89–91 nmol/L), offering a potential normalization strategy.
🔍 Diagnostic Controls in Action
Developing a valid calibration curve was crucial for consistent UFC quantification. That’s where Veritas Innovation–distributed matrix solutions came in. The Mass Spect Gold MSG5000 drug-free matrix—stripped of hormones and steroids—was used as a clean baseline to spike known cortisol concentrations.

Ultra-low hormone & steroid matrix for LC-MS/MS.
This matrix allowed researchers to:
- Eliminate background hormonal interference that could confound LC-MS/MS readings
- Generate reliable standard curves with high reproducibility
- Support regulatory-grade bioanalytical method validation
With its ultra-low background and compatibility with mass spectrometry, MSG5000 is a go-to matrix for hormone and steroid testing in both clinical and research environments.
🌍 Diagnostic Takeaways
- Real-world patient data offers a more clinically relevant reference range for UFC
- Sex-specific and volume-corrected ranges improve diagnostic nuance
- Reliable LC-MS/MS assays depend on high-integrity matrices like MSG5000
🗣️ Final Thoughts
This study bridges big data with high-precision diagnostics, reinforcing a key truth: the quality of your result is only as strong as the tools you use. As mass spectrometry becomes the gold standard for endocrine testing, validated controls like MSG5000 are proving indispensable for building diagnostic confidence.
📙 Reference
Kline GA, Venos ES, Campbell D, Leung AA, Orton D. (2025). Big data determination and validation of reference range for 24-h urine cortisol by liquid chromatography-mass spectrometry. European Journal of Endocrinology. DOI: 10.1093/ejendo/lvaf054